Chalco conductive truc tiep bong da anh tubular bus pipe conforms to ASTM B241, ASTM B 317M-07, GB/27676-2011, GB/T 33228-2016, IS:5082, IS:2673 etc. standards. Hot selling alloy products include 1350, 1060, 1070, 3003, 3A21, 6061, 6063, 6101 and some others.
1060 1070 alloy has good conductivity, low temperature rise, and low loss. Its tubular conductive product is a new type of conductor that replaces traditional rectangular, groove and strip busbar, and is one of the key equipment in transmission and transformation systems.Welcome contact
Why choose Chalco 1060 1070 EC truc tiep bong da anh busbar
- Chalco truc tiep bong da anh conductive bus pipes are produced by using the technology of casting hollow core billet + three roll rolling + cold stretching. The products have uniform and stable mechanical and electrical properties in both length and cross-sectional directions;
- Chalco conductive truc tiep bong da anh tube products use independently developed rare earth and heat-resistant truc tiep bong da anh alloy materials, which have excellent processing, welding, conductivity, and heat resistance properties;
- To meet diverse application needs, Chalco offers custom fabrication services such as bending, welding, cutting, and hole-drilling, along with advanced surface treatments like tin plating, copper cladding, and nickel plating to enhance conductivity and corrosion resistance.
- Chalco conductive truc tiep bong da anh tubes are widely used in power engineering such as transmission and transformation stations, as well as in power equipment such as transformers, and have established cooperation with many well-known enterprises.
Specification of Chalco 1060 1070 EC truc tiep bong da anh tubular busbar
Temper | H18 O |
Outer diameter | Φ60mm-Φ450mm |
Wall thickness | 3mm-15mm |
Length | The length of a single bus pipe can reach 15 meters; deviation:+15~+25mm |
Curvature | m/L<2.0mm |
Size and Deviation | Click to view the [Size and Deviation Table] |
Surface requirement | The surface is smooth and flat, without cracks, wrinkles, inclusions, deformation, or distortion. |
Product requirement | The finished pipeline is completely straight; High dimensional accuracy and high tensile strength; Not prone to discharge and corona. |
Profiles can be provided | Certificate of origin; Invoice and PL certified by Chamber of Commerce; Test certificate according to EN 10204 3.1; Other test reports that may be requested by the customer. |
Mechanical and electrical properties of Chalco 1060 1070 truc tiep bong da anh EC tubular bus bar
Alloy | 1060 | 1070 |
Temper | H18 | O |
Tensile Strength MPa | ≥150 | ≤95 |
Yield strength MPa | - | - |
Elongation % | ≥8 | ≤30 |
Thermal conductivity, (KrC xcm xs) | 0.5 | |
Electrical Conductivity, IACS% | 60 | 61 |
Temperature coefficient of electrical resistance, I/℃ | 0.0042 | |
Electrical Resistivity ρ, Ω·mm2/m | 0.029 | 0.028264 |
Poisson's Coefficient μ | 0.31 |
Product detail of Chalco 1060 & 1070 truc tiep bong da anh Conductive Bus Pipe
-
1060 truc tiep bong da anh Bus Pipe
Known for its high truc tiep bong da anh purity (≥99.6%), 1060 truc tiep bong da anh offers excellent conductivity and corrosion resistance. It is widely used in electrical applications requiring good electrical performance with moderate mechanical strength.
-
1070 truc tiep bong da anh Bus Pipe
With an even higher purity (≥99.7%), 1070 truc tiep bong da anh provides slightly better conductivity than 1060 and is ideal for environments demanding maximum electrical efficiency, such as substations and high-current equipment.
Specification | 1060 truc tiep bong da anh Bus Pipe | 1070 truc tiep bong da anh Bus Pipe |
truc tiep bong da anh Purity | ≥ 99.6% | ≥ 99.7% |
Conductivity (IACS) | ~60% | ~61% |
Corrosion Resistance | Excellent | Excellent |
Weldability | Good | Good |
Mechanical Strength | Moderate | Slightly lower than 1060 |
Application Suitability | Standard power transmission | High-efficiency power systems |
Purchase guide for 1060 & 1070 conductive truc tiep bong da anh bus pipes
Choosing the right conductive truc tiep bong da anh bus pipe depends on multiple factors such as conductivity requirements, installation environment, mechanical strength, and processing needs. This guide will help you compare 1060 and 1070 alloys and determine the most suitable option for your specific application.Quick Quote
- Choose 1060 when you need a cost-effective solution with reliable conductivity for general electrical systems or busbar frames.
- Choose 1070 when high conductivity is critical, such as for substations, jumpers, or large-scale grid connections.
- Consider additional factors such as required bending, surface treatment (e.g., tin plating), and corrosion environment when selecting the right alloy.
- For enhanced performance and durability, inquire about Chalco's custom fabrication and plating options.
Production and Processing Capability of Chalco 1060 & 1070 truc tiep bong da anh bus pipes
Chalco offers advanced production and precision processing capabilities to ensure high-quality, reliable 1060 & 1070 truc tiep bong da anh bus pipes for a wide range of electrical applications.Quick Quote
High-Purity Alloy Casting:Chalco uses high-purity 1060 and 1070 truc tiep bong da anh alloy billets, cast using advanced degassing and filtration systems to ensure superior conductivity and material stability.
Seamless Extrusion & Cold Drawing:Our seamless extrusion and multi-pass cold drawing techniques deliver excellent dimensional accuracy, smooth surfaces, and consistent mechanical and electrical properties across the full length of the pipe.
Custom Machining & Fabrication:Chalco offers flexible processing options, including precision cutting, bending, punching, welding, and hole-drilling to match specific electrical layouts and project needs.
Surface Treatment Options:To enhance performance in harsh or corrosive environments, we provide tin plating, nickel plating, and copper cladding to improve conductivity and resistance.
Long-Length Production:Single pipe lengths up to 15 meters are available, reducing the number of connections and improving efficiency in high-voltage transmission systems.
Advantage of Chalco 1060 1070 truc tiep bong da anh conductive bus pipe
Chalco 1060 & 1070 truc tiep bong da anh conductive bus pipes offer exceptional electrical conductivity, reliability, and versatility, making them ideal for a variety of power transmission and equipment applications.Quick Quote
Advantages of tubular busbar
- The tubular conductor has a larger cross-sectional area, reduces the influence of Skin effect and resistance loss, and improves the transmission efficiency;
- Reduce Corona Inception Voltage;
- Can be customized and assembled through various methods such as connection, bending, welding, etc., to adapt to different circuit layouts and topological structures.
Advantage of 1060 1070 truc tiep bong da anh tubular busbar
- The internal grain structure is dense, with strong corrosion resistance;
- Not easy to freeze, strong disaster resistance, and long service life;
- Good convective heat dissipation conditions, strong conductivity, high load-bearing capacity;
- Low power loss, equivalent to 40% of rectangular busbars and cables;
- Excellent mechanical processing, welding, and heat resistance performance;
- The installation area is small, and the combined busbar is 1/3 of the installation area of soft conductors.
Chalco other truc tiep bong da anh tubular buspipe products
Cooperative field of Chalco 1060 1070 truc tiep bong da anh conductive tubular busbar
Tubular conductors are a new type of conductor that replaces traditional transmission conductors such as rectangular, slot shaped, strip busbar, and flexible conductors.
Used for 400KV, 220KV, 132 KV, and 33 KV switchyards, as well as for connecting large pivot twist substations such as 220KV, 500KV, 750KV, and 1000KV with multi circuit power grid lines and main transformers.Quick Quote
Chalco 1060 1070 conductive truc tiep bong da anh tubes are mainly used in the power industry in the following areas:
- Current conductors in power construction projects;
- The conductor connection between the power grid transmission conductor and the substation;
- Jumpers in transmission lines;
- Connecting conductors in power equipment
- High current DC ice melting device, etc.
More electrical truc tiep bong da anh products in Chalco
- EC Grade xem bong da truc tiep Wire Rod
- EC Grade Electrical Busbar Supplier | Chalco
- EC tuong thuat truc tiep bong da Tubular Busbar Supplier
- truc tiep bong da anh plate strip foil for capacitor
- truc tiep bong da anh wire for electrical application
Size and deviation table of Chalco 1060 1070 truc tiep bong da anh tubular busbar
Size table reference table | ||||
SCH 40 Nominal size (in.) |
Outside diameter of tube (in.) |
Wall Thickness (in.) |
Area (sq. in.) |
Weight (lb/ft) |
1 | 1.315 | 0.133 | 0.4939 | 0.581 |
1.25 | 1.66 | 0.14 | 0.6685 | 0.786 |
1.5 | 1.9 | 0.145 | 0.7995 | 0.94 |
2 | 2.375 | 0.154 | 1.075 | 1.264 |
2.5 | 2.875 | 0.203 | 1.704 | 2.004 |
3 | 3.5 | 0.216 | 2.228 | 2.621 |
3.5 | 4 | 0.226 | 2.68 | 3.151 |
4 | 4.5 | 0.237 | 3.174 | 3.733 |
5 | 5.563 | 0.258 | 4.3 | 5.057 |
6 | 6.625 | 0.28 | 5.581 | 6.564 |
8 | 8.625 | 0.322 | 8.399 | 9.879 |
SCH 80 Nominal size (in.) |
Outside diameter of tube (in.) |
Wall Thickness (in.) |
Area (sq. in.) |
Weight (lb/ft) |
1 | 1.315 | 0.179 | 0.6388 | 0.751 |
1.25 | 1.66 | 0.191 | 0.8815 | 1.037 |
1.5 | 1.9 | 0.2 | 1.068 | 1.256 |
2 | 2.375 | 0.218 | 1.477 | 1.737 |
2.5 | 2.875 | 0.276 | 2.254 | 2.65 |
3 | 3.5 | 0.3 | 3.016 | 3.547 |
3.5 | 4 | 0.318 | 3.678 | 4.326 |
4 | 4.5 | 0.337 | 4.407 | 5.183 |
5 | 5.563 | 0.375 | 6.112 | 7.188 |
6 | 6.625 | 0.432 | 8.405 | 9.884 |
8 | 8.625 | 0.5 | 12.763 | 15.009 |
Wall thickness deviation | ||||||||
Nominal wall thickness | 3-5 | >5 -8 | >8-10 | >10-12 | >12-15 | >15 -20 | ||
Ordinary level | Average & nominal wall thickness | ±0.30 | ±0.50 | ±0.70 | ±0.9 | ±1.10 | ±1.3 | |
Any & nominal wall thickness | H14 | ±0.40 | ±0.60 | ±0.90 | ±1.10 | ±1.3 | ±1.6 | |
T5A, T6, T10 | ±12% of the specified wall thickness, maximum value is 1.90 | |||||||
High precision level | Average & nominal wall thickness | ±0.15 | ±0.20 | ±0.38 | ±0.50 | ±0.70 | ±1.00 | |
Any & nominal wall thickness | H14 | ±0.2 | ±0.3 | ±0.5 | ±0.76 | ±1.00 | ±1.4 | |
T5A, T6, T10 | ±10% of the specified wall thickness, maximum value is 1.70 |
Outer diameter deviation | |||
Nominal OD | Ordinary level | ||
Average & Nominal outer diameter | Any & Nominal outer diameter | ||
H14 | T5A, T6, T10 | ||
50.00-80.00 | ±0.24 | ±0.30 | ±0.45 |
80.00-120.00 | ±0.35 | ±0.40 | ±0.62 |
120.00-150.00 | ±0.45 | ±0.50 | ±0.75 |
150.00-200.00 | ±0.65 | ±0.7 | ±1.00 |
200.00-250.00 | ±0.77 | ± | ±1.2 |
250.00-300.00 | ±0.96 | ±1 | ±1.5 |
300.00-350.00 | ±1.3 | ±1.4 | ±1.8 |
High precision level | |||
Nominal OD | Average & Nominal outer diameter | Any & Nominal outer diameter | |
H14 | T5A, T6, T10 | ||
50.00-80.00 | ±0.15 | ±0.15 | ±0.3 |
80.00-120.00 | ±0.20 | ±0.20 | ±0.41 |
120.00-150.00 | ±0.25 | ±0.25 | ±0.5 |
150.00-200.00 | ±0.38 | ±0.38 | ±0.76 |
200.00-250.00 | ±0.50 | ±0.5 | ±1.00 |
250.00-300.00 | ±0.64 | ±0.64 | ±1.25 |
300.00-350.00 | ±0.9 | ±0.9 | ±1.6 |